MindPeace™
MindPeace is a personal protection device designed to reduce radiation exposure of your neck, face and brain.
PRODUCT SPECIFICATIONS
Purpose
MindPeace™ is a personal radiation protection device designed to reduce scatter radiation exposure to the neck, face, and lower head during fluoroscopy-guided procedures.
Protection
- Designed to provide extended coverage of the thyroid, carotid region, jawline, and lower cranial area
- Evaluations report mean radiation attenuation of up to ~95–97% in high-exposure interventional settings
- May reduce scatter radiation toward the eyes when used as part of a comprehensive protection strategy
Design & Ergonomics
- Patented extended-panel design engineered to protect from oblique scatter radiation below the field
- Designed to allow free neck movement without chin contact against the protective panels
- Ergonomic assessments report high comfort during prolonged procedures
Materials
- Lead-free radiation-attenuating textile
- Eliminates risks associated with lead dust exposure
- Durable, soft-touch fabric designed for repeated clinical use
Fit & Compatibility
- Adjustable closure system for secure, individualized fit
- Designed to integrate with HeadPeace™ for combined head-and-neck protection
- Compatible with leaded eyewear
Care
- Designed for repeated clinical use
- Clean per institutional infection-control protocols
SIZE & FIT
Sizing is based on neck circumference and overall fit preference. MindPeace™ is adjustable to allow fine-tuning for comfort and secure positioning.
Available Sizes
- Small: 36–38 cm (14–15 in)
- Medium: 39–41 cm (15.5–16 in)
- Large: 42–44 cm (16.5–17.5 in)
- Extra Large: 45–47 cm (18–18.5 in)
Fit Guidance
- Designed to sit comfortably around the neck without restricting movement
- Extended protective panels allow coverage without chin contact
- If between sizes, choose based on comfort preference and procedural positioning
SCIENTIFIC DATA
MindPeace™ has been evaluated in phantom and clinical settings to assess radiation attenuation and usability during fluoroscopy-guided procedures.
Key Findings
- Demonstrated reduction in radiation exposure to the thyroid, neck, jawline, and lower cranial regions
- Mean attenuation of up to ~95–97% reported in neuroradiological and interventional use cases
- Evaluations conducted under fluoroscopic workflows representative of real-world practice
- Assessments reported high comfort with no adverse impact on posture or procedural workflow
Additional resources:
Phantom Study Summary · Clinical Evaluation Summary
Clinical Perspective
“Most surgeons underestimate how much radiation they absorb over a career.”
— Dr. Peter Derman, MD
Texas Back Institute
Why Dr. Derman prioritizes head and neck protection in daily practice
%20(600%20x%20200%20px)%20(1).png?width=600&height=200&name=Untitled%20(1128%20x%20191%20px)%20(600%20x%20200%20px)%20(1).png)